Customization: | Available |
---|---|
Transport Package: | Veneer Case |
Trademark: | Sinpo |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
X1 axis (beam) | ||
Measuring range | 100mm | |
Straightness | 0.7μm/60mm | |
Moving speed | 0 ~ 4mm/s (at any speed) | |
Resolution | 0.5 | |
Indicating accuracy | ± (2.5+2L/100) , where L: Drive length (mm) | |
Measuring direction | Backwards | |
Detecting method | Grating ruler | |
Z1 shaft (sensor) | ||
Measuring range | 12mm | |
Resolution | 0.03 | |
Detecting method | Precision inductive transducer | |
Indicating accuracy | ± (1.5+|4H|/50) | |
Upward/Downward movement of measuring needle | Arc motion | |
Direction of measuring needle | Downwards | |
Lifting mode of measuring needle | Manual | |
Measuring force | 6mN | |
Radius of measuring needle | 25 hard alloy | |
Ascending angle | Upward: 75° Downward: 85° | |
Measuring speed | 0.02 mm/s~4 mm/s (at any speed) | |
Z2 axis (column) | ||
Height of pillar | 200mm | |
Maximum measuring height | 100mm | |
Moving mode | CNC or joystick | |
Moving speed | 0.1~8/mm (at any speed) | |
Collection and control system | ||
System transmission mode | PCI | |
System resolution | 16-bit AD | |
Control mode of movement | CNC drive or handle drive | |
Data processing | ||
Graphic scaling | Adjust the size by the mouse pulley | |
Auxiliary line | Add some auxiliary lines anywhere in the graph | |
Data fitting | When the work-piece cannot be measured completely for one time, it can be divided into several times for measurement, and then combine these results | |
Elimination of abnormal points | Manual elimination or automatic elimination of abnormal convex and concave points | |
Graphic movement | Drag the graph arbitrarily within the coordinates by using mouse | |
Graphic rotation | Rotation of arbitrary angle | |
Local zoom | Select a zone/area to zoom in or zoom out the graph | |
SPC quality analysis | Bar chart, normal distribution diagram | |
Mode of document output | PDF, Excel, CAD | |
Edit of measurement report | Can output standard reports, which can be edited by the users according to their needs | |
Operating parameters | ||
Power supply | 400W, AC220V, 50HZ | |
Environment | Temperature: 10 ~ 30 ºC; Relative humidity: < 85% |